| MEASURED
PARAMETERS |
Optional Display |
Comms. |
Relays |
Optional Analog |
| Alarm |
Pulse |
| True RMS Voltage |
(Volts L-L & L-N) |
Average RMS per Phase |
x |
x |
x |
|
x |
| Direct Voltage input: |
Up to 690 V L-L & 400 L-N |
Real-time per phase |
|
x |
x |
|
x |
| PT Ratio: |
1.0 - 6500.0 |
|
|
|
|
|
|
| Range of Reading: |
1 - 999,000 V |
|
|
|
|
|
|
| Accuracy: |
+/- 0.25% FS |
|
|
|
|
|
|
| True RMS Current |
(Amps) |
Average RMS per Phase |
x |
x |
x |
|
x |
| Secondary Current Input: |
5A or 1A |
Real-time per phase |
|
x |
x |
|
x |
| CT Ratio: |
1 to 50,000 |
|
|
|
|
|
|
| Range of Reading: |
0 - 60,000 A |
|
|
|
|
|
|
| Accuracy: |
+/- 0.25% FS |
|
|
|
|
|
|
| Neutral Current |
(AMPS) |
Average RMS |
x |
x |
x |
|
x |
| Range of Reading: |
0 - 60,000 A |
Real-time |
|
x |
|
|
|
| Accuracy: |
+/- 0.5% FS) |
|
|
|
|
|
|
| Frequency |
(Hz) |
Average RMS |
x |
x |
x |
|
x |
| Range of Reading: |
45.00 to 55.00 Hz |
Real-time |
|
x |
x |
|
x |
| Accuracy: |
+/-0.5% Reading |
|
|
|
|
|
|
| Power Factor |
(PF) |
Average total |
x |
x |
x |
|
x |
| Range of Reading: |
0.0 to 1.000 Lead/Lag |
Average per phase |
x |
x |
|
|
|
| Accuracy: |
+/- 1% FS |
Real-time total |
|
x |
|
|
x |
| |
|
Real-time per phase |
|
x |
|
|
|
| Phase Rotation |
Positive, Negative, Error |
Pos, Neg, Err |
x |
x |
x |
|
|
| POWER FUNCTIONS |
| Active Power |
(Watts) |
Average Total |
x |
x |
x |
|
x |
| Range of Reading: |
-2,000,000 to 2,000,000 kW |
Average per phase |
x |
x |
|
|
|
| Accuracy: |
+/- 0.5% FS |
Real-time total |
|
x |
|
|
x |
| |
|
Real-time per phase |
|
x |
|
|
|
| Reactive Power |
(vars) |
Average Total |
x |
x |
x |
|
x |
| Range of Reading: |
-2,000,000 to 2,000,000 kvar |
Average per phase |
x |
x |
|
|
|
| Accuracy: |
+/- 0.5% FS |
Real-time total |
|
x |
|
|
x |
| |
|
Real-time per-phase |
|
x |
|
|
|
| Apparent Power |
(VA) |
Average Total |
x |
x |
x |
|
x |
| Range of Reading: |
0 to 2,000,000 kVA |
Average per phase |
x |
x |
|
|
|
| Accuracy: |
+/- 0.5% FS |
Real-time total |
|
x |
|
|
x |
| |
|
Real-time per-phase |
|
x |
|
|
|
| ENERGY FUNCTIONS |
| Active Energy |
(MWh) |
Total Import |
x |
x |
|
x |
|
| Range of Reading: |
0 - 99,999 MWh |
Total Export |
x |
x |
|
x |
|
| Accuracy: |
As Power |
Import per phase |
x |
x |
|
|
|
| Reactive Energy |
(Mvarh) |
Total Import |
x |
x |
|
x |
|
| Range of Reading: |
0 - 99,999 MWh |
Total Export |
x |
x |
|
x |
|
| Accuracy: |
As Power |
Import per phase |
x |
x |
|
|
|
| |
|
Total net |
|
x |
|
|
|
| Apparent Energy |
(MVAh) |
Total |
x |
x |
|
x |
|
| Range of Reading: |
0 - 99,999 MWh |
Per phase |
x |
x |
|
|
|
| Accuracy: |
As Power |
|
|
|
|
|
|
| DEMAND FUNCTIONS |
| Current demand |
(Amps) |
Demand per phase |
|
x |
x |
|
|
| (same as Current) |
|
Max Demand per phase |
x |
x |
|
|
|
| Active Power Demand |
(Watts) |
Demand |
|
x |
x |
|
|
| (same as Active Power) |
|
Accumulated Demand |
|
x |
x |
|
x |
| |
|
Sliding Demand |
|
x |
x |
|
|
| |
|
Max Sliding Demand |
x |
x |
|
|
|
| Apparent Power Demand |
(VA) |
Demand |
|
x |
x |
|
|
| (same as Apparent Power) |
|
Maximum Demand |
x |
x |
|
|
|
| |
|
Accumulated Demand |
|
x |
x |
|
x |
| |
|
Sliding Demand |
|
x |
x |
|
|
| |
|
Max Sliding Demand |
|
x |
x |
|
|
| QUALITY OF SUPPLY FUNCTIONS |
| Harmonics |
|
|
|
|
|
|
|
| Accuracy: |
+/- 1.5% FS |
Voltage THD per phase |
x |
x |
x |
|
|
| |
|
Current THD per phase |
x |
x |
x |
|
|
| |
|
Current TDD per phase |
x |
x |
x |
|
|
| |
|
K-factor per phase |
|
x |
|
|
|
| ADDITIONAL FUNCTIONS |
| |
|
Remote Relay Control |
|
x |
x |
|
x |
| |
|
Digital Input Status |
x |
x |
|
|
|
| |
|
Relay Output Status |
x |
x |
|
|
|
| |
|
Alarm Trigger Status |
|
x |
|
|
|
| OPTIONS |
Codes |
| HARMONICS AND DEMAND DISTORTION |
| No THD & TDD |
0 |
| THD & TDD |
H |
| VOLTAGE INPUTS |
| 690V AC Nominal Voltage Input |
0 |
| 120V AC Nominal Voltage Input |
U |
| CURRENT INPUTS |
| 5 Ampere |
5 |
| 1 Ampere |
1 |
| POWER SUPPLY |
| 90-264V AC and 110-290V DC (Standard) |
ACDC |
| 10-18V DC |
1DC |
| 18-36V DC |
2DC |
| 38-72V DC |
3DC |
| COMMUNICATION PROTOCOLS |
| Modbus & ASCII |
0 |
| DNP3.0 & ASCII |
1P |
| ANALOG OPTION |
| No Analog Output |
0 |
| +/- 1mA (0+/-1) |
A1 |
| 0-20mA (0-10-20) |
A2 |
| 0-1mA (0-0.5-1) |
A3 |
| 4-20mA (4-12-20) |
A4 |
| REAL TIME CLOCK |
| No Real Time Clock |
0 |
| Real Time Clock |
RTC |
| |
|
| RDM 091 |
| |
|
| OPTIONS - |
Codes |
| MOUNTING |
| Panel Mounted |
M |
| Portable |
P |
| Retrofit (W/Brackets) |
R |
| CABLE LENGTH |
| 0.4 Meter (1 Ft.) - (Supplied with R Option) |
1L |
| 1.8 Meter (6 Ft.) |
2L |
| 3.0 Meter (10 Ft.) |
3L |
|